Total
11936 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-7523 | 1 Cygwin | 1 Cygwin | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| Cygwin versions 1.7.2 up to and including 1.8.0 are vulnerable to buffer overflow vulnerability in wcsxfrm/wcsxfrm_l functions resulting into denial-of-service by crashing the process or potential hijack of the process running with administrative privileges triggered by specially crafted input string. | |||||
| CVE-2017-7467 | 1 Minicom Project | 1 Minicom | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A buffer overflow flaw was found in the way minicom before version 2.7.1 handled VT100 escape sequences. A malicious terminal device could potentially use this flaw to crash minicom, or execute arbitrary code in the context of the minicom process. | |||||
| CVE-2017-6791 | 1 Cisco | 1 Unified Communications Manager | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability in the Trust Verification Service (TVS) of Cisco Unified Communications Manager could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper handling of Transport Layer Security (TLS) traffic by the affected software. An attacker could exploit this vulnerability by generating incomplete traffic streams. A successful exploit could allow the attacker to deny access to the TVS for an affected device, resulting in a DoS condition, until an administrator restarts the service. Known Affected Releases 10.0(1.10000.24) 10.5(2.10000.5) 11.0(1.10000.10) 9.1(2.10000.28). Cisco Bug IDs: CSCux21905. | |||||
| CVE-2017-6753 | 1 Cisco | 20 Webex Event Center, Webex Meeting Center, Webex Meetings and 17 more | 2019-10-09 | 9.3 HIGH | 8.8 HIGH |
| A vulnerability in Cisco WebEx browser extensions for Google Chrome and Mozilla Firefox could allow an unauthenticated, remote attacker to execute arbitrary code with the privileges of the affected browser on an affected system. This vulnerability affects the browser extensions for Cisco WebEx Meetings Server, Cisco WebEx Centers (Meeting Center, Event Center, Training Center, and Support Center), and Cisco WebEx Meetings when they are running on Microsoft Windows. The vulnerability is due to a design defect in the extension. An attacker who can convince an affected user to visit an attacker-controlled web page or follow an attacker-supplied link with an affected browser could exploit the vulnerability. If successful, the attacker could execute arbitrary code with the privileges of the affected browser. The following versions of the Cisco WebEx browser extensions are affected: Versions prior to 1.0.12 of the Cisco WebEx extension on Google Chrome, Versions prior to 1.0.12 of the Cisco WebEx extension on Mozilla Firefox. Cisco Bug IDs: CSCvf15012 CSCvf15020 CSCvf15030 CSCvf15033 CSCvf15036 CSCvf15037. | |||||
| CVE-2017-6745 | 1 Cisco | 1 Videoscape Distribution Suite For Television | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability in the cache server within Cisco Videoscape Distribution Suite (VDS) for Television 3.2(5)ES1 could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on a targeted appliance. The vulnerability is due to excessive mapped connections exhausting the allotted resources within the system. An attacker could exploit this vulnerability by sending large amounts of inbound traffic to a device with the intention of overloading certain resources. A successful exploit could cause the device to reload, resulting in a DoS condition. Cisco Bug IDs: CSCvc39260. | |||||
| CVE-2017-6742 | 1 Cisco | 1 Ios Xe | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve54313. | |||||
| CVE-2017-6741 | 1 Cisco | 1 Ios Xe | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve66658. | |||||
| CVE-2017-6740 | 1 Cisco | 1 Ios | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve66601. | |||||
| CVE-2017-6739 | 1 Cisco | 1 Ios | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve66540. | |||||
| CVE-2017-6738 | 1 Cisco | 1 Ios | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve89865, CSCsy56638. | |||||
| CVE-2017-6737 | 1 Cisco | 1 Ios | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve60402. | |||||
| CVE-2017-6037 | 1 We-con | 1 Levi Studio Hmi Editor | 2019-10-09 | 9.3 HIGH | 8.8 HIGH |
| A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow when a maliciously crafted project file is run by the system. | |||||
| CVE-2017-6035 | 1 We-con | 1 Levi Studio Hmi Editor | 2019-10-09 | 9.3 HIGH | 8.8 HIGH |
| A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system. | |||||
| CVE-2017-6025 | 1 Codesys | 1 Web Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. | |||||
| CVE-2017-3223 | 1 Dahuasecurity | 2 Ip Camera, Ip Camera Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the 'password' field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera's Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803. | |||||
| CVE-2017-3196 | 2 Microsoft, Rawether Project | 2 Windows, Rawether | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| PCAUSA Rawether framework does not properly validate BPF data, allowing a crafted malicious BPF program to perform operations on memory outside of its typical bounds on the driver's receipt of network packets. Local attackers can exploit this issue to execute arbitrary code with SYSTEM privileges. | |||||
| CVE-2017-2668 | 2 Fedoraproject, Redhat | 4 389 Directory Server, Enterprise Linux Desktop, Enterprise Linux Server and 1 more | 2019-10-09 | 4.3 MEDIUM | 6.5 MEDIUM |
| 389-ds-base before versions 1.3.5.17 and 1.3.6.10 is vulnerable to an invalid pointer dereference in the way LDAP bind requests are handled. A remote unauthenticated attacker could use this flaw to make ns-slapd crash via a specially crafted LDAP bind request, resulting in denial of service. | |||||
| CVE-2017-2575 | 1 Libbpg Project | 1 Libbpg | 2019-10-09 | 4.3 MEDIUM | 6.5 MEDIUM |
| A vulnerability was found while fuzzing libbpg 0.9.7. It is a NULL pointer dereference issue due to missing check of the return value of function malloc in the BPG encoder. This vulnerability appeared while converting a malicious JPEG file to BPG. | |||||
| CVE-2017-2344 | 1 Juniper | 1 Junos | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| A routine within an internal Junos OS sockets library is vulnerable to a buffer overflow. Malicious exploitation of this issue may lead to a denial of service (kernel panic) or be leveraged as a privilege escalation through local code execution. The routines are only accessible via programs running on the device itself, and veriexec restricts arbitrary programs from running on Junos OS. There are no known exploit vectors utilizing signed binaries shipped with Junos OS itself. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67; 12.3X48 prior to 12.3X48-D51, 12.3X48-D55; 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R2-S10, 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D122, 14.1X53-D45, 14.1X53-D50; 14.2 prior to 14.2R4-S9, 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F2-S18, 15.1F6-S7, 15.1R4-S8, 15.1R5-S5, 15.1R6-S1, 15.1R7; 15.1X49 prior to 15.1X49-D100; 15.1X53 prior to 15.1X53-D231, 15.1X53-D47, 15.1X53-D48, 15.1X53-D57, 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R4-S4, 16.1R5; 16.2 prior to 16.2R2; 17.1 prior to 17.1R1-S3, 17.1R2; 17.2 prior to 17.2R1-S1, 17.2R2; 17.2X75 prior to 17.2X75-D30. No other Juniper Networks products or platforms are affected by this issue. | |||||
| CVE-2017-16751 | 1 Deltaww | 1 Delta Industrial Automation Screen Editor | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code. | |||||
