Vulnerabilities (CVE)

Filtered by CWE-200
Total 7971 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-32770 1 Gatsbyjs 1 Gatsby-source-wordpress 2022-10-25 5.0 MEDIUM 7.5 HIGH
Gatsby is a framework for building websites. The gatsby-source-wordpress plugin prior to versions 4.0.8 and 5.9.2 leaks .htaccess HTTP Basic Authentication variables into the app.js bundle during build-time. Users who are not initializing basic authentication credentials in the gatsby-config.js are not affected. A patch has been introduced in gatsby-source-wordpress@4.0.8 and gatsby-source-wordpress@5.9.2 which mitigates the issue by filtering all variables specified in the `auth: { }` section. Users that depend on this functionality are advised to upgrade to the latest release of gatsby-source-wordpress, run `gatsby clean` followed by a `gatsby build`. One may manually edit the app.js file post-build as a workaround.
CVE-2021-32658 1 Nextcloud 1 Nextcloud 2022-10-25 2.1 LOW 4.6 MEDIUM
Nextcloud Android is the Android client for the Nextcloud open source home cloud system. Due to a timeout issue the Android client may not properly clean all sensitive data on account removal. This could include sensitive key material such as the End-to-End encryption keys. It is recommended that the Nextcloud Android App is upgraded to 3.16.1
CVE-2021-32707 1 Nextcloud 1 Nextcloud Mail 2022-10-25 4.0 MEDIUM 4.3 MEDIUM
Nextcloud Mail is a mail app for Nextcloud. In versions prior to 1.9.6, the Nextcloud Mail application does not, by default, render images in emails to not leak the read state. The privacy filter failed to filter images with a `background-image` CSS attribute. Note that the images were still passed through the Nextcloud image proxy, and thus there was no IP leakage. The issue was patched in version 1.9.6 and 1.10.0. No workarounds are known to exist.
CVE-2021-32731 1 Xwiki 1 Xwiki 2022-10-25 5.0 MEDIUM 5.3 MEDIUM
XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. Between (and including) versions 13.1RC1 and 13.1, the reset password form reveals the email address of users just by giving their username. The problem has been patched on XWiki 13.2RC1. As a workaround, it is possible to manually modify the `resetpasswordinline.vm` to perform the changes made to mitigate the vulnerability.
CVE-2021-32695 1 Nextcloud 1 Nextcloud 2022-10-25 4.3 MEDIUM 3.3 LOW
Nextcloud Android app is the Android client for Nextcloud. In versions prior to 3.16.1, a malicious app on the same device could have gotten access to the shared preferences of the Nextcloud Android application. This required user-interaction as a victim had to initiate the sharing flow and choose the malicious app. The shared preferences contain some limited private data such as push tokens and the account name. The vulnerability is patched in version 3.16.1.
CVE-2021-32690 1 Helm 1 Helm 2022-10-25 5.0 MEDIUM 8.6 HIGH
Helm is a tool for managing Charts (packages of pre-configured Kubernetes resources). In versions of helm prior to 3.6.1, a vulnerability exists where the username and password credentials associated with a Helm repository could be passed on to another domain referenced by that Helm repository. This issue has been resolved in 3.6.1. There is a workaround through which one may check for improperly passed credentials. One may use a username and password for a Helm repository and may audit the Helm repository in order to check for another domain being used that could have received the credentials. In the `index.yaml` file for that repository, one may look for another domain in the `urls` list for the chart versions. If there is another domain found and that chart version was pulled or installed, the credentials would be passed on.
CVE-2021-32717 1 Shopware 1 Shopware 2022-10-25 5.0 MEDIUM 7.5 HIGH
Shopware is an open source eCommerce platform. In versions prior to 6.4.1.1 private files publicly accessible with Cloud Storage providers when the hashed URL is known. Users are recommend to first change their configuration to set the correct visibility according to the documentation. The visibility must be at the same level as `type`. When the Storage is saved on Amazon AWS we recommending disabling public access to the bucket containing the private files: https://docs.aws.amazon.com/AmazonS3/latest/userguide/access-control-block-public-access.html. Otherwise, update to Shopware 6.4.1.1 or install or update the Security plugin (https://store.shopware.com/en/detail/index/sArticle/518463/number/Swag136939272659) and run the command `./bin/console s3:set-visibility` to correct your cloud file visibilities.
CVE-2021-32716 1 Shopware 1 Shopware 2022-10-25 4.0 MEDIUM 4.9 MEDIUM
Shopware is an open source eCommerce platform. In versions prior to 6.4.1.1 the admin api has exposed some internal hidden fields when an association has been loaded with a to many reference. Users are recommend to update to version 6.4.1.1. You can get the update to 6.4.1.1 regularly via the Auto-Updater or directly via the download overview. For older versions of 6.1, 6.2, and 6.3, corresponding security measures are also available via a plugin.
CVE-2021-24948 1 Posimyth 1 The Plus Addons For Elementor 2022-10-25 5.0 MEDIUM 7.5 HIGH
The Plus Addons for Elementor - Pro WordPress plugin before 5.0.7 does not validate the qvquery parameter of the tp_get_dl_post_info_ajax AJAX action, which could allow unauthenticated users to retrieve sensitive information, such as private and draft posts
CVE-2021-22815 1 Schneider-electric 55 Ap9922 Battery Management System, Apc Rack Power Distribution Units, Galaxy 3500 and 52 more 2022-10-25 5.0 MEDIUM 5.3 MEDIUM
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
CVE-2021-21591 1 Dell 3 Emc Unity Operating Environment, Emc Unity Xt Operating Environment, Emc Unityvsa Operating Environment 2022-10-24 4.6 MEDIUM 6.7 MEDIUM
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CVE-2021-21590 1 Dell 3 Emc Unity Operating Environment, Emc Unity Xt Operating Environment, Emc Unityvsa Operating Environment 2022-10-24 4.6 MEDIUM 6.7 MEDIUM
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CVE-2021-21596 1 Dell 2 Openmanage Enterprise, Openmanage Enterprise-modular 2022-10-24 5.8 MEDIUM 8.8 HIGH
Dell OpenManage Enterprise versions 3.4 through 3.6.1 and Dell OpenManage Enterprise Modular versions 1.20.00 through 1.30.00, contain a remote code execution vulnerability. A malicious attacker with access to the immediate subnet may potentially exploit this vulnerability leading to information disclosure and a possible elevation of privileges.
CVE-2021-26566 1 Synology 7 Diskstation Manager, Diskstation Manager Unified Controller, Skynas and 4 more 2022-10-24 6.8 MEDIUM 9.0 CRITICAL
Insertion of sensitive information into sent data vulnerability in synorelayd in Synology DiskStation Manager (DSM) before 6.2.3-25426-3 allows man-in-the-middle attackers to execute arbitrary commands via inbound QuickConnect traffic.
CVE-2021-27422 1 Ge 38 Multilin B30, Multilin B30 Firmware, Multilin B90 and 35 more 2022-10-24 5.0 MEDIUM 7.5 HIGH
GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication.
CVE-2021-41239 1 Nextcloud 1 Nextcloud Server 2022-10-24 5.0 MEDIUM 5.3 MEDIUM
Nextcloud server is a self hosted system designed to provide cloud style services. In affected versions the User Status API did not consider the user enumeration settings by the administrator. This allowed a user to enumerate other users on the instance, even when user listings where disabled. It is recommended that the Nextcloud Server is upgraded to 20.0.14, 21.0.6 or 22.2.1. There are no known workarounds.
CVE-2021-41181 1 Nextcloud 1 Talk 2022-10-24 2.1 LOW 2.4 LOW
Nextcloud talk is a self hosting messaging service. In versions prior to 12.3.0 the Nextcloud Android Talk application did not properly detect the lockscreen state when a call was incoming. If an attacker got physical access to the locked phone, and the victim received a phone call the attacker could gain access to the chat messages and files of the user. It is recommended that the Nextcloud Android Talk App is upgraded to 12.3.0. There are no known workarounds.
CVE-2021-23195 1 Fresenius-kabi 8 Agilia Connect, Agilia Connect Firmware, Agilia Partner Maintenance Software and 5 more 2022-10-24 5.0 MEDIUM 5.3 MEDIUM
Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 has the option for automated indexing (directory listing) activated. When accessing a directory, a web server delivers its entire content in HTML form. If an index file does not exist and directory listing is enabled, all content of the directory will be displayed, allowing an attacker to identify and access files on the server.
CVE-2021-41158 1 Freeswitch 1 Freeswitch 2022-10-24 5.0 MEDIUM 7.5 HIGH
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to version 1.10.7, an attacker can perform a SIP digest leak attack against FreeSWITCH and receive the challenge response of a gateway configured on the FreeSWITCH server. This is done by challenging FreeSWITCH's SIP requests with the realm set to that of the gateway, thus forcing FreeSWITCH to respond with the challenge response which is based on the password of that targeted gateway. Abuse of this vulnerability allows attackers to potentially recover gateway passwords by performing a fast offline password cracking attack on the challenge response. The attacker does not require special network privileges, such as the ability to sniff the FreeSWITCH's network traffic, to exploit this issue. Instead, what is required for this attack to work is the ability to cause the victim server to send SIP request messages to the malicious party. Additionally, to exploit this issue, the attacker needs to specify the correct realm which might in some cases be considered secret. However, because many gateways are actually public, this information can easily be retrieved. The vulnerability appears to be due to the code which handles challenges in `sofia_reg.c`, `sofia_reg_handle_sip_r_challenge()` which does not check if the challenge is originating from the actual gateway. The lack of these checks allows arbitrary UACs (and gateways) to challenge any request sent by FreeSWITCH with the realm of the gateway being targeted. This issue is patched in version 10.10.7. Maintainers recommend that one should create an association between a SIP session for each gateway and its realm to make a check be put into place for this association when responding to challenges.
CVE-2021-3602 2 Buildah Project, Redhat 4 Buildah, Enterprise Linux, Enterprise Linux For Ibm Z Systems and 1 more 2022-10-24 1.9 LOW 5.5 MEDIUM
An information disclosure flaw was found in Buildah, when building containers using chroot isolation. Running processes in container builds (e.g. Dockerfile RUN commands) can access environment variables from parent and grandparent processes. When run in a container in a CI/CD environment, environment variables may include sensitive information that was shared with the container in order to be used only by Buildah itself (e.g. container registry credentials).