CVE-2020-12037 1 Baxter 4 Prismaflex, Prismaflex Firmware, Prismax and 1 more 2020-07-14 5.0 MEDIUM 7.5 HIGH
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
CVE-2020-12036 1 Baxter 4 Prismaflex, Prismaflex Firmware, Prismax and 1 more 2020-07-14 5.0 MEDIUM 7.5 HIGH
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
CVE-2020-12040 1 Baxter 2 Sigma Spectrum Infusion System, Sigma Spectrum Infusion System Firmware 2020-07-09 5.0 MEDIUM 9.8 CRITICAL
Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack.
CVE-2020-12008 1 Baxter 4 Em1200, Em1200 Firmware, Em2400 and 1 more 2020-07-08 5.0 MEDIUM 7.5 HIGH
Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI.
CVE-2020-10628 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2020-07-07 5.0 MEDIUM 7.5 HIGH
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.
CVE-2020-10624 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2020-07-07 5.0 MEDIUM 7.5 HIGH
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
CVE-2020-5594 1 Mitsubishielectric 10 Melsec-fx, Melsec-fx Firmware, Melsec-l and 7 more 2020-07-01 7.5 HIGH 9.8 CRITICAL
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
CVE-2020-2013 1 Paloaltonetworks 1 Pan-os 2020-05-18 6.8 MEDIUM 8.8 HIGH
A cleartext transmission of sensitive information vulnerability in Palo Alto Networks PAN-OS Panorama that discloses an authenticated PAN-OS administrator's PAN-OS session cookie. When an administrator issues a context switch request into a managed firewall with an affected PAN-OS Panorama version, their PAN-OS session cookie is transmitted over cleartext to the firewall. An attacker with the ability to intercept this network traffic between the firewall and Panorama can access the administrator's account and further manipulate devices managed by Panorama. This issue affects: PAN-OS 7.1 versions earlier than 7.1.26; PAN-OS 8.1 versions earlier than 8.1.13; PAN-OS 9.0 versions earlier than 9.0.6; PAN-OS 9.1 versions earlier than 9.1.1; All version of PAN-OS 8.0;
CVE-2020-4092 1 Hcltech 1 Hcl Nomad 2020-05-12 5.0 MEDIUM 5.3 MEDIUM
"If port encryption is not enabled on the Domino Server, HCL Nomad on Android and iOS Platforms will communicate in clear text and does not currently have a user interface option to change the setting to request an encrypted communication channel with the Domino server. This can potentially expose sensitive information including but not limited to server names, user IDs and document content."
CVE-2011-3022 1 Google 1 Chrome 2020-04-16 5.0 MEDIUM N/A
translate/translate_manager.cc in Google Chrome before 17.0.963.56 and 19.x before 19.0.1036.7 uses an HTTP session to exchange data for translation, which allows remote attackers to obtain sensitive information by sniffing the network.
CVE-2020-6997 1 Moxa 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more 2020-03-26 5.0 MEDIUM 7.5 HIGH
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext.
CVE-2020-7003 1 Moxa 40 Iologik 2512, Iologik 2512-hspa, Iologik 2512-hspa-t and 37 more 2020-03-26 5.0 MEDIUM 7.5 HIGH
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is transmitted over some web applications in clear text.
CVE-2019-12122 1 Onap 1 Open Network Automation Platform 2020-03-20 4.0 MEDIUM 6.5 MEDIUM
An issue was discovered in ONAP Portal through Dublin. By executing a call to ONAPPORTAL/portalApi/loggedinUser, an attacker who possesses a user's cookie may retrieve that user's password from the database. All Portal setups are affected.
CVE-2020-0884 1 Microsoft 2 Visual Studio 2017, Visual Studio 2019 2020-03-17 4.3 MEDIUM 3.7 LOW
A spoofing vulnerability exists in Microsoft Visual Studio as it includes a reply URL that is not secured by SSL, aka 'Microsoft Visual Studio Spoofing Vulnerability'.
CVE-2019-5107 1 Wago 1 E\!cockpit 2020-03-13 5.0 MEDIUM 7.5 HIGH
A cleartext transmission vulnerability exists in the network communication functionality of WAGO e!Cockpit version 1.5.1.1. An attacker with access to network traffic can easily intercept, interpret, and manipulate data coming from, or destined for e!Cockpit. This includes passwords, configurations, and binaries being transferred to endpoints.
CVE-2019-9101 1 Moxa 12 Mb3170, Mb3170 Firmware, Mb3180 and 9 more 2020-03-12 5.0 MEDIUM 7.5 HIGH
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server.
CVE-2020-9550 1 Rubetek 2 Smarthome, Smarthome Firmware 2020-03-06 7.5 HIGH 9.8 CRITICAL
Rubetek SmartHome 2020 devices use unencrypted 433 MHz communication between controllers and beacons, allowing an attacker to sniff and spoof beacon requests remotely.
CVE-2020-5399 2 Cloudfoundry, Pivotal Software 2 Credhub, Cloud Foundry Cf-deployment 2020-02-27 5.8 MEDIUM 7.4 HIGH
Cloud Foundry CredHub, versions prior to 2.5.10, connects to a MySQL database without TLS even when configured to use TLS. A malicious user with access to the network between CredHub and its MySQL database may eavesdrop on database connections and thereby gain unauthorized access to CredHub and other components.
CVE-2020-7984 1 Solarwinds 1 N-central 2020-02-05 5.0 MEDIUM 7.5 HIGH
SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent & Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration.
CVE-2015-7542 3 Aquamaniac, Debian, Opensuse 3 Gwenhywfar, Debian Linux, Leap 2020-02-03 5.0 MEDIUM 5.3 MEDIUM
A vulnerability exists in libgwenhywfar through 4.12.0 due to the usage of outdated bundled CA certificates.