Filtered by vendor Tenda
Subscribe
Total
741 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-40071 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2022-09-21 | N/A | 7.5 HIGH |
| Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, formSetDeviceName. | |||||
| CVE-2022-40070 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2022-09-21 | N/A | 7.5 HIGH |
| Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via bin/httpd, function: formSetFirewallCfg. | |||||
| CVE-2022-40069 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2022-09-21 | N/A | 7.5 HIGH |
| ]Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetSysTime. | |||||
| CVE-2022-40068 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2022-09-21 | N/A | 7.5 HIGH |
| Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: formSetQosBand. | |||||
| CVE-2022-40067 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2022-09-21 | N/A | 7.5 HIGH |
| Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: formSetVirtualSer. | |||||
| CVE-2022-38829 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2022-09-17 | N/A | 9.8 CRITICAL |
| Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg. | |||||
| CVE-2022-38830 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2022-09-17 | N/A | 9.8 CRITICAL |
| Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status. | |||||
| CVE-2022-38831 | 1 Tenda | 2 Rx9 Pro, Rx9 Pro Firmware | 2022-09-17 | N/A | 9.8 CRITICAL |
| Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList | |||||
| CVE-2022-38314 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2022-09-10 | N/A | 9.8 CRITICAL |
| Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo. | |||||
| CVE-2022-38313 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2022-09-10 | N/A | 9.8 CRITICAL |
| Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo. | |||||
| CVE-2022-38312 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2022-09-10 | N/A | 9.8 CRITICAL |
| Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind. | |||||
| CVE-2022-38311 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2022-09-10 | N/A | 9.8 CRITICAL |
| Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet. | |||||
| CVE-2022-38310 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2022-09-10 | N/A | 9.8 CRITICAL |
| Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg. | |||||
| CVE-2022-38309 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2022-09-10 | N/A | 9.8 CRITICAL |
| Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg. | |||||
| CVE-2022-36587 | 1 Tenda | 2 G3, G3 Firmware | 2022-09-09 | N/A | 9.8 CRITICAL |
| In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by sprintf in function in the httpd binary. | |||||
| CVE-2022-36585 | 1 Tenda | 2 G3, G3 Firmware | 2022-09-09 | N/A | 9.8 CRITICAL |
| In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, in httpd binary, the addDhcpRule function has a buffer overflow caused by sscanf. | |||||
| CVE-2022-36586 | 1 Tenda | 2 G3, G3 Firmware | 2022-09-09 | N/A | 9.8 CRITICAL |
| In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by strcpy in function 0x869f4 in the httpd binary. | |||||
| CVE-2022-36584 | 1 Tenda | 2 G3, G3 Firmware | 2022-09-08 | N/A | 9.8 CRITICAL |
| In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, the getsinglepppuser function has a buffer overflow caused by sscanf. | |||||
| CVE-2022-36571 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-09-02 | N/A | 7.2 HIGH |
| Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting. | |||||
| CVE-2022-36570 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-09-02 | N/A | 7.2 HIGH |
| Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg. | |||||