CVE-2018-7786 1 Schneider-electric 1 U.motion Builder 2018-08-28 4.3 MEDIUM 6.1 MEDIUM
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.
CVE-2018-7776 1 Schneider-electric 1 U.motion Builder 2018-08-28 4.3 MEDIUM 4.3 MEDIUM
The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.
CVE-2018-7772 1 Schneider-electric 1 U.motion Builder 2018-08-28 6.8 MEDIUM 8.8 HIGH
The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query to determine whether a user is logged in is subject to SQL injection on the loginSeed parameter, which can be embedded in the HTTP cookie of the request.
CVE-2018-7771 1 Schneider-electric 1 U.motion Builder 2018-08-28 6.0 MEDIUM 8.0 HIGH
The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A directory traversal vulnerability allows a caller with standard user privileges to write arbitrary php files anywhere in the web service directory tree.
CVE-2018-7764 1 Schneider-electric 1 U.motion Builder 2018-08-28 4.3 MEDIUM 4.3 MEDIUM
The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4. There is a directory traversal vulnerability in the processing of the 's' parameter of the applet.
CVE-2018-7773 1 Schneider-electric 1 U.motion Builder 2018-08-23 6.8 MEDIUM 8.8 HIGH
The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the sessionid input parameter.
CVE-2018-7769 1 Schneider-electric 1 U.motion Builder 2018-08-21 6.8 MEDIUM 8.8 HIGH
The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.
CVE-2018-7767 1 Schneider-electric 1 U.motion Builder 2018-08-21 6.8 MEDIUM 8.8 HIGH
The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the type input parameter.
CVE-2018-7774 1 Schneider-electric 1 U.motion Builder 2018-08-21 6.8 MEDIUM 8.8 HIGH
The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter.
CVE-2018-7768 1 Schneider-electric 1 U.motion Builder 2018-08-21 6.8 MEDIUM 8.8 HIGH
The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the tpl input parameter.
CVE-2018-7766 1 Schneider-electric 1 U.motion Builder 2018-08-21 6.8 MEDIUM 8.8 HIGH
The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.
CVE-2013-0657 1 Schneider-electric 1 Interactive Graphical Scada System 2018-08-21 10.0 HIGH N/A
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
CVE-2018-7758 1 Schneider-electric 46 Micom P141, Micom P141 Firmware, Micom P142 and 43 more 2018-05-29 3.3 LOW 6.5 MEDIUM
A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number.
CVE-2013-0663 1 Schneider-electric 3 Modicon M340, Modicon Premium, Modicon Quantum Plc 2018-05-24 6.8 MEDIUM N/A
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.
CVE-2018-7244 1 Schneider-electric 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more 2018-05-23 5.0 MEDIUM 5.3 MEDIUM
An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained.
CVE-2016-5809 1 Schneider-electric 6 Ion5000, Ion7300, Ion7500 and 3 more 2018-05-20 6.8 MEDIUM 8.8 HIGH
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
CVE-2018-7239 1 Schneider-electric 13 Atv12 Dtm, Atv212 Dtm, Atv312 Dtm and 10 more 2018-03-26 6.8 MEDIUM 7.8 HIGH
A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.
CVE-2017-9970 1 Schneider-electric 1 Struxureon Gateway 2018-03-09 9.0 HIGH 7.2 HIGH
A remote code execution vulnerability exists in Schneider Electric's StruxureOn Gateway versions 1.1.3 and prior. Uploading a zip which contains carefully crafted metadata allows for the file to be uploaded to any directory on the host machine information which could lead to remote code execution.
CVE-2017-9968 1 Schneider-electric 1 Igss Mobile 2018-03-09 4.3 MEDIUM 5.9 MEDIUM
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack.
CVE-2017-9965 1 Schneider-electric 1 Pelco Videoxpert 2018-02-13 5.0 MEDIUM 5.8 MEDIUM
An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.