Filtered by vendor Siemens
Subscribe
Total
1752 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-31894 | 1 Siemens | 8 Simatic Pcs 7, Simatic Pcs 7 Firmware, Simatic Pdm and 5 more | 2022-08-10 | 7.2 HIGH | 8.8 HIGH |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software. | |||||
| CVE-2021-40366 | 1 Siemens | 2 Climatix Pol909, Climatix Pol909 Firmware | 2022-08-09 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit. | |||||
| CVE-2021-42029 | 1 Siemens | 71 Simatic S7-1200 Cpu, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1212c and 68 more | 2022-08-09 | 7.2 HIGH | 7.8 HIGH |
| A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server. | |||||
| CVE-2020-17437 | 4 Contiki-os, Open-iscsi Project, Siemens and 1 more | 21 Contiki, Open-iscsi, Sentron 3va Com100 and 18 more | 2022-08-08 | 6.4 MEDIUM | 8.2 HIGH |
| An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for large values of the Urgent pointer bytes, the data pointer can point to memory that is way beyond the data buffer in uip_process in uip.c. | |||||
| CVE-2020-28396 | 1 Siemens | 6 Sicam A8000 Cp-8000, Sicam A8000 Cp-8000 Firmware, Sicam A8000 Cp-8021 and 3 more | 2022-08-06 | 4.9 MEDIUM | 7.3 HIGH |
| A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V16), SICAM A8000 CP-8021 (All versions < V16), SICAM A8000 CP-8022 (All versions < V16). A web server misconfiguration of the affected device can cause insecure ciphers usage by a user´s browser. An attacker in a privileged position could decrypt the communication and compromise confidentiality and integrity of the transmitted information. | |||||
| CVE-2020-13987 | 4 Contiki-os, Open-iscsi Project, Siemens and 1 more | 11 Contiki, Open-iscsi, Sentron 3va Com100 and 8 more | 2022-08-06 | 5.0 MEDIUM | 7.5 HIGH |
| An issue was discovered in Contiki through 3.0. An Out-of-Bounds Read vulnerability exists in the uIP TCP/IP Stack component when calculating the checksums for IP packets in upper_layer_chksum in net/ipv4/uip.c. | |||||
| CVE-2021-44478 | 1 Siemens | 2 Polarion Alm, Polarion Subversion Webclient | 2022-07-28 | 4.3 MEDIUM | 6.1 MEDIUM |
| A vulnerability has been identified in Polarion ALM (All versions < V21 R2 P2), Polarion WebClient for SVN (All versions). A cross-site scripting is present due to improper neutralization of data sent to the web page through the SVN WebClient in the affected product. An attacker could exploit this to execute arbitrary code and extract sensitive information by sending a specially crafted link to users with administrator privileges. | |||||
| CVE-2020-25226 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-28 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. | |||||
| CVE-2020-15799 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-28 | 7.1 HIGH | 6.5 MEDIUM |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. | |||||
| CVE-2021-42021 | 1 Siemens | 6 Siveillance Video Dlna Server, Siveillance Video Management Software 2019 R1, Siveillance Video Management Software 2019 R2 and 3 more | 2022-07-25 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application’s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks. | |||||
| CVE-2021-44003 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2022-07-25 | 4.3 MEDIUM | 5.5 MEDIUM |
| A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll is vulnerable to use of uninitialized memory while parsing user supplied TIFF files. This could allow an attacker to cause a denial-of-service condition. | |||||
| CVE-2019-5317 | 2 Arubanetworks, Siemens | 3 Instant, Scalance W1750d, Scalance W1750d Firmware | 2022-07-22 | 4.6 MEDIUM | 6.8 MEDIUM |
| A local authentication bypass vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x: 6.5.4.15 and below; Aruba Instant 8.3.x: 8.3.0.11 and below; Aruba Instant 8.4.x: 8.4.0.5 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability. | |||||
| CVE-2022-34464 | 1 Siemens | 4 Sicam Gridedge Essential Arm, Sicam Gridedge Essential Gds Arm, Sicam Gridedge Essential Gds Intel and 1 more | 2022-07-19 | 2.1 LOW | 5.5 MEDIUM |
| A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions), SICAM GridEdge Essential Intel (All versions < V2.7.3), SICAM GridEdge Essential with GDS ARM (All versions), SICAM GridEdge Essential with GDS Intel (All versions < V2.7.3). Affected software uses an improperly protected file to import SSH keys. Attackers with access to the filesystem of the host on which SICAM GridEdge runs, are able to inject a custom SSH key to that file. | |||||
| CVE-2022-29884 | 1 Siemens | 6 Sicam A8000 Cp-8000, Sicam A8000 Cp-8000 Firmware, Sicam A8000 Cp-8021 and 3 more | 2022-07-19 | 7.1 HIGH | 7.5 HIGH |
| A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition. | |||||
| CVE-2022-29560 | 1 Siemens | 22 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Mx5000re and 19 more | 2022-07-19 | 10.0 HIGH | 7.2 HIGH |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < 2.15.1), RUGGEDCOM ROX MX5000RE (All versions < 2.15.1), RUGGEDCOM ROX RX1400 (All versions < 2.15.1), RUGGEDCOM ROX RX1500 (All versions < 2.15.1), RUGGEDCOM ROX RX1501 (All versions < 2.15.1), RUGGEDCOM ROX RX1510 (All versions < 2.15.1), RUGGEDCOM ROX RX1511 (All versions < 2.15.1), RUGGEDCOM ROX RX1512 (All versions < 2.15.1), RUGGEDCOM ROX RX1524 (All versions < 2.15.1), RUGGEDCOM ROX RX1536 (All versions < 2.15.1), RUGGEDCOM ROX RX5000 (All versions < 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user. | |||||
| CVE-2021-44222 | 1 Siemens | 1 Simatic Easie Core Package | 2022-07-15 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The underlying MQTT service of affected systems does not perform authentication in the default configuration. This could allow an unauthenticated remote attacker to send arbitrary messages to the service and thereby issue arbitrary requests in the affected system. | |||||
| CVE-2021-44221 | 1 Siemens | 1 Simatic Easie Core Package | 2022-07-15 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow an remote attacker to trigger a denial of service of the affected system. | |||||
| CVE-2022-34274 | 1 Siemens | 1 Pads Viewer | 2022-07-15 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-039) | |||||
| CVE-2022-34275 | 1 Siemens | 1 Pads Viewer | 2022-07-15 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-040) | |||||
| CVE-2022-34276 | 1 Siemens | 1 Pads Viewer | 2022-07-15 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-041) | |||||