Filtered by vendor Siemens
Subscribe
Total
1752 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-23449 | 1 Siemens | 2 Simatic Energy Manager Basic, Simatic Energy Manager Pro | 2022-04-19 | 6.9 MEDIUM | 7.3 HIGH |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path. | |||||
| CVE-2022-23450 | 1 Siemens | 2 Simatic Energy Manager Basic, Simatic Energy Manager Pro | 2022-04-19 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges. | |||||
| CVE-2022-23448 | 1 Siemens | 2 Simatic Energy Manager Basic, Simatic Energy Manager Pro | 2022-04-19 | 7.2 HIGH | 7.8 HIGH |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges. | |||||
| CVE-2019-19242 | 5 Canonical, Oracle, Redhat and 2 more | 5 Ubuntu Linux, Mysql Workbench, Enterprise Linux and 2 more | 2022-04-19 | 4.3 MEDIUM | 5.9 MEDIUM |
| SQLite 3.30.1 mishandles pExpr->y.pTab, as demonstrated by the TK_COLUMN case in sqlite3ExprCodeTarget in expr.c. | |||||
| CVE-2021-42059 | 2 Insyde, Siemens | 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more | 2022-04-18 | 7.2 HIGH | 6.7 MEDIUM |
| An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver. | |||||
| CVE-2019-19925 | 8 Debian, Netapp, Opensuse and 5 more | 12 Debian Linux, Cloud Backup, Backports Sle and 9 more | 2022-04-15 | 5.0 MEDIUM | 7.5 HIGH |
| zipfileUpdate in ext/misc/zipfile.c in SQLite 3.30.1 mishandles a NULL pathname during an update of a ZIP archive. | |||||
| CVE-2019-19923 | 8 Debian, Netapp, Opensuse and 5 more | 12 Debian Linux, Cloud Backup, Backports Sle and 9 more | 2022-04-15 | 5.0 MEDIUM | 7.5 HIGH |
| flattenSubquery in select.c in SQLite 3.30.1 mishandles certain uses of SELECT DISTINCT involving a LEFT JOIN in which the right-hand side is a view. This can cause a NULL pointer dereference (or incorrect results). | |||||
| CVE-2019-19926 | 8 Debian, Netapp, Opensuse and 5 more | 12 Debian Linux, Cloud Backup, Backports Sle and 9 more | 2022-04-15 | 5.0 MEDIUM | 7.5 HIGH |
| multiSelect in select.c in SQLite 3.30.1 mishandles certain errors during parsing, as demonstrated by errors from sqlite3WindowRewrite() calls. NOTE: this vulnerability exists because of an incomplete fix for CVE-2019-19880. | |||||
| CVE-2019-19880 | 8 Debian, Netapp, Opensuse and 5 more | 12 Debian Linux, Cloud Backup, Backports Sle and 9 more | 2022-04-15 | 5.0 MEDIUM | 7.5 HIGH |
| exprListAppendList in window.c in SQLite 3.30.1 allows attackers to trigger an invalid pointer dereference because constant integer values in ORDER BY clauses of window definitions are mishandled. | |||||
| CVE-2019-19646 | 5 Netapp, Oracle, Siemens and 2 more | 6 Cloud Backup, Ontap Select Deploy Administration Utility, Mysql Workbench and 3 more | 2022-04-15 | 7.5 HIGH | 9.8 CRITICAL |
| pragma.c in SQLite through 3.30.1 mishandles NOT NULL in an integrity_check PRAGMA command in certain cases of generated columns. | |||||
| CVE-2019-19645 | 5 Netapp, Oracle, Siemens and 2 more | 6 Cloud Backup, Ontap Select Deploy Administration Utility, Mysql Workbench and 3 more | 2022-04-15 | 2.1 LOW | 5.5 MEDIUM |
| alter.c in SQLite through 3.30.1 allows attackers to trigger infinite recursion via certain types of self-referential views in conjunction with ALTER TABLE statements. | |||||
| CVE-2019-19317 | 4 Netapp, Oracle, Siemens and 1 more | 5 Cloud Backup, Ontap Select Deploy Administration Utility, Mysql Workbench and 2 more | 2022-04-15 | 7.5 HIGH | 9.8 CRITICAL |
| lookupName in resolve.c in SQLite 3.30.1 omits bits from the colUsed bitmask in the case of a generated column, which allows attackers to cause a denial of service or possibly have unspecified other impact. | |||||
| CVE-2019-19244 | 4 Canonical, Oracle, Siemens and 1 more | 4 Ubuntu Linux, Mysql Workbench, Sinec Infrastructure Network Services and 1 more | 2022-04-15 | 5.0 MEDIUM | 7.5 HIGH |
| sqlite3Select in select.c in SQLite 3.30.1 allows a crash if a sub-select uses both DISTINCT and window functions, and also has certain ORDER BY usage. | |||||
| CVE-2021-31784 | 2 Opendesign, Siemens | 2 Drawings Sdk, Comos | 2022-04-15 | 6.8 MEDIUM | 7.8 HIGH |
| An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6 on all supported by ODA platforms in static configuration. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. | |||||
| CVE-2021-32946 | 2 Opendesign, Siemens | 4 Drawings Sdk, Comos, Jt2go and 1 more | 2022-04-15 | 6.8 MEDIUM | 7.8 HIGH |
| An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process. | |||||
| CVE-2021-32944 | 2 Opendesign, Siemens | 4 Drawings Sdk, Comos, Jt2go and 1 more | 2022-04-15 | 6.8 MEDIUM | 7.8 HIGH |
| A use-after-free issue exists in the DGN file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process. | |||||
| CVE-2021-32950 | 2 Opendesign, Siemens | 4 Drawings Sdk, Comos, Jt2go and 1 more | 2022-04-15 | 5.8 MEDIUM | 7.1 HIGH |
| An out-of-bounds read issue exists within the parsing of DXF files in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations. | |||||
| CVE-2021-46162 | 1 Siemens | 1 Simcenter Femap | 2022-04-15 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15048) | |||||
| CVE-2017-2681 | 1 Siemens | 155 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 Pn Io and 152 more | 2022-04-12 | 6.1 MEDIUM | 6.5 MEDIUM |
| Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. | |||||
| CVE-2017-2680 | 1 Siemens | 183 S110 Pn, Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware and 180 more | 2022-04-12 | 6.1 MEDIUM | 6.5 MEDIUM |
| Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. | |||||
