Filtered by vendor Siemens
Subscribe
Total
1752 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2019-13926 | 1 Siemens | 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more | 2021-05-05 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device. | |||||
| CVE-2021-22663 | 2 Hornerautomation, Siemens | 2 Cscape, Cscape | 2021-05-03 | 6.8 MEDIUM | 7.8 HIGH |
| Cscape (All versions prior to 9.90 SP3.5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
| CVE-2021-27389 | 1 Siemens | 2 Opcenter Quality, Qms Automotive | 2021-04-30 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection. | |||||
| CVE-2021-25670 | 1 Siemens | 1 Tecnomatix Robotexpert | 2021-04-30 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12608) | |||||
| CVE-2015-7973 | 5 Canonical, Freebsd, Netapp and 2 more | 9 Ubuntu Linux, Freebsd, Clustered Data Ontap and 6 more | 2021-04-26 | 5.8 MEDIUM | 6.5 MEDIUM |
| NTP before 4.2.8p6 and 4.3.x before 4.3.90, when configured in broadcast mode, allows man-in-the-middle attackers to conduct replay attacks by sniffing the network. | |||||
| CVE-2015-7974 | 4 Debian, Netapp, Ntp and 1 more | 8 Debian Linux, Clustered Data Ontap, Oncommand Balance and 5 more | 2021-04-26 | 4.0 MEDIUM | 7.7 HIGH |
| NTP 4.x before 4.2.8p6 and 4.3.x before 4.3.90 do not verify peer associations of symmetric keys when authenticating packets, which might allow remote attackers to conduct impersonation attacks via an arbitrary trusted key, aka a "skeleton key." | |||||
| CVE-2020-7586 | 1 Siemens | 4 Simatic Pcs 7, Simatic Process Device Manager, Simatic Step 7 and 1 more | 2021-04-22 | 4.6 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information. | |||||
| CVE-2020-7585 | 1 Siemens | 4 Simatic Pcs 7, Simatic Process Device Manager, Simatic Step 7 and 1 more | 2021-04-22 | 4.6 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information. | |||||
| CVE-2015-8214 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2021-04-22 | 9.7 HIGH | N/A |
| A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions < V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs' configuration was stored on their corresponding CPUs. | |||||
| CVE-2021-25676 | 1 Siemens | 8 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M-800 and 5 more | 2021-04-20 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically. | |||||
| CVE-2017-11175 | 1 Siemens | 1 Fin Stack | 2021-04-20 | 4.3 MEDIUM | 6.1 MEDIUM |
| In J2 Innovations FIN Stack 4.0, the authentication webform is vulnerable to reflected XSS via the query string to /login. | |||||
| CVE-2015-7855 | 4 Debian, Netapp, Ntp and 1 more | 11 Debian Linux, Clustered Data Ontap, Data Ontap and 8 more | 2021-04-19 | 4.0 MEDIUM | 6.5 MEDIUM |
| The decodenetnum function in ntpd in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to cause a denial of service (assertion failure) via a 6 or mode 7 packet containing a long data value. | |||||
| CVE-2021-22651 | 2 Luxion, Siemens | 8 Keyshot, Keyshot Network Rendering, Keyshot Viewer and 5 more | 2021-03-23 | 6.8 MEDIUM | 7.8 HIGH |
| When loading a specially crafted file, Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are, while processing the extraction of temporary files, suffering from a directory traversal vulnerability, which allows an attacker to store arbitrary scripts into automatic startup folders. | |||||
| CVE-2021-22645 | 2 Luxion, Siemens | 8 Keyshot, Keyshot Network Rendering, Keyshot Viewer and 5 more | 2021-03-23 | 6.8 MEDIUM | 7.8 HIGH |
| Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to an attack because the .bip documents display a “load” command, which can be pointed to a .dll from a remote network share. As a result, the .dll entry point can be executed without sufficient UI warning. | |||||
| CVE-2021-22647 | 2 Luxion, Siemens | 8 Keyshot, Keyshot Network Rendering, Keyshot Viewer and 5 more | 2021-03-23 | 6.8 MEDIUM | 7.8 HIGH |
| Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to multiple out-of-bounds write issues while processing project files, which may allow an attacker to execute arbitrary code. | |||||
| CVE-2021-22643 | 2 Luxion, Siemens | 8 Keyshot, Keyshot Network Rendering, Keyshot Viewer and 5 more | 2021-03-23 | 6.8 MEDIUM | 7.8 HIGH |
| Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code. | |||||
| CVE-2020-25240 | 1 Siemens | 1 Sinema Remote Connect Server | 2021-03-18 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service. | |||||
| CVE-2020-25241 | 1 Siemens | 14 Simatic Mv420 Sr-b, Simatic Mv420 Sr-b Body, Simatic Mv420 Sr-b Body Firmware and 11 more | 2021-03-18 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP RST packages. An attacker could exploit this to terminate arbitrary TCP sessions. | |||||
| CVE-2020-25239 | 1 Siemens | 1 Sinema Remote Connect Server | 2021-03-18 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights. | |||||
| CVE-2021-25673 | 1 Siemens | 1 Simatic S7-plcsim | 2021-03-18 | 4.9 MEDIUM | 5.5 MEDIUM |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service. | |||||