| CVE-2019-13927 | 1 Siemens | 32 Pxa30-w0, Pxa30-w0 Firmware, Pxa30-w1 and 29 more | 2019-12-30 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability has been identified in Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server (All firmware versions < V6.00.320). The device contains a vulnerability that could allow an attacker to cause a denial of service condition on the device's web server by sending a specially crafted HTTP message to the web server port (tcp/80). The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device's web service. While the device itself stays operational, the web server responds with HTTP status code 404 (Not found) to any further request. A reboot is required to recover the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-13932 | 1 Siemens | 1 Xhq | 2019-12-19 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web application requests could be manipulated, causing the the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated. A successful attack could allow the import of scripts or generation of malicious links. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-13931 | 1 Siemens | 1 Xhq | 2019-12-19 | 3.5 LOW | 5.4 MEDIUM |
| A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-13930 | 1 Siemens | 1 Xhq | 2019-12-19 | 5.8 MEDIUM | 8.1 HIGH |
| A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2013-3634 | 1 Siemens | 7 Scalance X200-4p Irt, Scalance X200irt Firmware, Scalance X201-3p Irt and 4 more | 2019-12-12 | 7.5 HIGH | N/A |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials. | |||||
| CVE-2013-3633 | 1 Siemens | 7 Scalance X200-4p Irt, Scalance X200irt Firmware, Scalance X201-3p Irt and 4 more | 2019-12-12 | 8.0 HIGH | N/A |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The user privileges for the web interface are only enforced on client side and not properly verified on server side. Therefore, an attacker is able to execute privileged commands using an unprivileged account. | |||||
| CVE-2016-8673 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2019-12-12 | 6.8 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server at port 80/TCP or port 443/TCP of the affected devices could allow remote attackers to perform actions with the permissions of an authenticated user, provided the targeted user has an active session and is induced to trigger the malicious request. | |||||
| CVE-2016-8672 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2019-12-12 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission. | |||||
| CVE-2019-13935 | 1 Siemens | 1 Polarion | 2019-12-05 | 3.5 LOW | 5.4 MEDIUM |
| Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2. | |||||
| CVE-2019-13936 | 1 Siemens | 1 Polarion | 2019-12-05 | 3.5 LOW | 5.4 MEDIUM |
| Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2. | |||||
| CVE-2019-13934 | 1 Siemens | 1 Polarion | 2019-12-05 | 3.5 LOW | 5.4 MEDIUM |
| Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2. | |||||
| CVE-2019-10935 | 1 Siemens | 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime | 2019-10-10 | 6.5 MEDIUM | 7.2 HIGH |
| A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. | |||||
| CVE-2019-13920 | 1 Siemens | 1 Sinema Remote Connect Server | 2019-10-09 | 4.3 MEDIUM | 4.3 MEDIUM |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-13918 | 1 Siemens | 1 Sinema Remote Connect Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2018-5381 | 4 Canonical, Debian, Quagga and 1 more | 5 Ubuntu Linux, Debian Linux, Quagga and 2 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| The Quagga BGP daemon (bgpd) prior to version 1.2.3 has a bug in its parsing of "Capabilities" in BGP OPEN messages, in the bgp_packet.c:bgp_capability_msg_parse function. The parser can enter an infinite loop on invalid capabilities if a Multi-Protocol capability does not have a recognized AFI/SAFI, causing a denial of service. | |||||
| CVE-2018-5380 | 4 Canonical, Debian, Quagga and 1 more | 5 Ubuntu Linux, Debian Linux, Quagga and 2 more | 2019-10-09 | 4.0 MEDIUM | 4.3 MEDIUM |
| The Quagga BGP daemon (bgpd) prior to version 1.2.3 can overrun internal BGP code-to-string conversion tables used for debug by 1 pointer value, based on input. | |||||
| CVE-2018-5379 | 5 Canonical, Debian, Quagga and 2 more | 10 Ubuntu Linux, Debian Linux, Quagga and 7 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| The Quagga BGP daemon (bgpd) prior to version 1.2.3 can double-free memory when processing certain forms of UPDATE message, containing cluster-list and/or unknown attributes. A successful attack could cause a denial of service or potentially allow an attacker to execute arbitrary code. | |||||
| CVE-2018-4861 | 1 Siemens | 2 Scalance M875, Scalance M875 Firmware | 2019-10-09 | 4.0 MEDIUM | 4.9 MEDIUM |
| A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could potentially read and download arbitrary files from the device's file system. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2018-4860 | 1 Siemens | 2 Scalance M875, Scalance M875 Firmware | 2019-10-09 | 9.0 HIGH | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2018-4859 | 1 Siemens | 2 Scalance M875, Scalance M875 Firmware | 2019-10-09 | 9.0 HIGH | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||