Filtered by vendor Rockwellautomation
Subscribe
Total
241 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-11999 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2020-06-24 | 5.5 MEDIUM | 8.1 HIGH |
| FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data. | |||||
| CVE-2020-12034 | 1 Rockwellautomation | 5 Eds Subsystem, Rslinx, Rslinx Enterprise and 2 more | 2020-05-22 | 4.8 MEDIUM | 8.2 HIGH |
| Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. | |||||
| CVE-2020-6967 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2020-03-27 | 10.0 HIGH | 9.8 CRITICAL |
| In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data. | |||||
| CVE-2020-6990 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 10.0 HIGH | 9.8 CRITICAL |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller. | |||||
| CVE-2020-6984 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 5.0 MEDIUM | 7.5 HIGH |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable. | |||||
| CVE-2020-6988 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 5.0 MEDIUM | 7.5 HIGH |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials. | |||||
| CVE-2020-6980 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 2.1 LOW | 3.3 LOW |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext. | |||||
| CVE-2019-10955 | 1 Rockwellautomation | 11 Compactlogix 5370 L1, Compactlogix 5370 L1 Firmware, Compactlogix 5370 L2 and 8 more | 2020-02-10 | 5.8 MEDIUM | 6.1 MEDIUM |
| In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user’s machine. | |||||
| CVE-2013-2807 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2020-02-10 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 | |||||
| CVE-2013-2806 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2020-02-10 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 | |||||
| CVE-2013-2805 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2020-02-10 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 | |||||
| CVE-2010-5305 | 1 Rockwellautomation | 5 Plc5 1785-lx, Plc5 1785-lx Firmware, Rslogix and 2 more | 2020-02-10 | 7.5 HIGH | 9.8 CRITICAL |
| The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services. | |||||
| CVE-2019-13521 | 1 Rockwellautomation | 1 Arena Simulation | 2020-02-03 | 6.8 MEDIUM | 7.8 HIGH |
| A maliciously crafted program file opened by an unsuspecting user of Rockwell Automation Arena Simulation Software version 16.00.00 and earlier may result in the limited exposure of information related to the targeted workstation. Rockwell Automation has released version 16.00.01 of Arena Simulation Software to address the reported vulnerabilities. | |||||
| CVE-2019-13519 | 1 Rockwellautomation | 1 Arena Simulation | 2020-02-03 | 6.8 MEDIUM | 7.8 HIGH |
| A maliciously crafted program file opened by an unsuspecting user of Rockwell Automation Arena Simulation Software version 16.00.00 and earlier may result in the limited exposure of information related to the targeted workstation. Rockwell Automation has released version 16.00.01 of Arena Simulation Software to address the reported vulnerabilities. | |||||
| CVE-2019-13527 | 1 Rockwellautomation | 1 Arena Simulation Software | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| In Rockwell Automation Arena Simulation Software Cat. 9502-Ax, Versions 16.00.00 and earlier, a maliciously crafted Arena file opened by an unsuspecting user may result in the use of a pointer that has not been initialized. | |||||
| CVE-2018-8843 | 1 Rockwellautomation | 1 Arena | 2019-10-09 | 4.3 MEDIUM | 5.5 MEDIUM |
| Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data.. | |||||
| CVE-2018-19016 | 1 Rockwellautomation | 2 Ethernet\/ip Web Server Module 1756-eweb, Ethernet\/ip Web Server Module 1768-eweb | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation EtherNet/IP Web Server Modules 1756-EWEB (includes 1756-EWEBK) Version 5.001 and earlier, and CompactLogix 1768-EWEB Version 2.005 and earlier. A remote attacker could send a crafted UDP packet to the SNMP service causing a denial-of-service condition to occur until the affected product is restarted. | |||||
| CVE-2018-18981 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services. | |||||
| CVE-2018-14829 | 1 Rockwellautomation | 1 Rslinx | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code. | |||||
| CVE-2018-14827 | 1 Rockwellautomation | 1 Rslinx | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality. | |||||